Distributor of lockers, racks, mezzanine and shelving products.EHow Auto gets you on the fast track with repair, maintenance, and shopping advice.Whether youre jump starting a battery or insuring a new car, we can help.Jamb Construction Details Steel Door Institute.American National Standard.Recommended Erection Instructions for Steel Frames.ANSISDI A2.Revision of ANSISDI A2.Scope.Recommended methods for the installation of steel frames for swinging doors in a variety of wall conditions, commonly used in commercial buildings, are covered within this standard.FH03JAU_INTDOR_01-2.jpg' alt='How To Install A Steel Door In Block' title='How To Install A Steel Door In Block' />The installation of transomsidelight or panel type frames and single or multiple borrowed lights are not covered in this standard.It is not the intention of this document to obstruct the development of alternative installation methods, nor is it intended to restrict frame installation solely to the wall types noted herein.Although this document is commonly referenced for severe windstorm installations, critical performance requirements such as type, quantity, and location of anchors shall be as indicated in the manufacturers published Approvals or Listings.Reference documents.SDI 1.E 2. 00.Prime Painted Materials Alert.SDI 1.F 2. 01.Butted Frames Rough Opening Sizes.SDI 1.J 2. 01.Back Coating of Frames.SDI 1.Manufacturing Tolerances for Standard Steel Doors and Frames.How To Install A Steel Door In Block' title='How To Install A Steel Door In Block' />NFPA 8.Standard for Fire Doors and Other Opening Protectives National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 0.UL1.C 2. 00. 9 Standard for Safety Positive Pressure Fire Tests of Door Assemblies.ANSISDI A2.R2. 00. 8 Recommended Specifications for Standard Doors and Frames.HMMA 8.Installation and Storage of Hollow Metal Doors and Frames.HMMA 8.Tolerances and Clearances for Commercial Hollow Metal Doors and Frames.Further information on wall construction, anchoring, details, manufacturing tolerances or installation may be found in the following SDI 1.Standard Steel Doors and Frames for Modular Masonry Construction.SDI 1.Recommended Standard Details for Steel Doors, Frames, Accessories and Related Components.SDI 1.Installation and Troubleshooting Guide for Standard Steel Doors and Frames.SDI 1.D 2. 00.Energy-Efficiency-2.jpg' alt='How To Install A Steel Door In Block' title='How To Install A Steel Door In Block' />Electric Strikes in Stud Walls.Metrication. How To Update A House Built In The 1990S Edge . Standard dimensions used in this document are in inch pound units.Metric values, where applicable, are included in parenthesis for reference only.These are soft conversion approximates.TOP2 Storage and Preliminary Assembly see SDI 1.E, and ANSISDI A2.All frames, including knocked down, shall be stored under cover.Knocked down frames shall be placed flat on at least 4 1.Assembled frames shall be stored vertically.The units shall be placed on at least 4 1.The use of non vented plastic or canvas shelters that can create a humidity chamber shall be avoided.Refer to project specifications for required cleanup and touchup work.Back Coating see SDI 1.J for further information2.When temperature conditions necessitate the use of anti freezing agents in plaster or mortar, the inside of the frame shall be coated at the jobsite with a corrosion resistant coating by the contractor responsible for installation.Grouting of frames see ANSISDI A2.Where grouting is required in masonry installations, frames shall be braced or fastened in such a way that will prevent the pressure of the grout from deforming the frame members.Grout shall be mixed to provide a 4 1.Grout mixed to a thinner pumpable consistency shall not be used.Standard mortar protection in frames is not intended for thin consistency grout.Steel frames, including fire rated frames, do not require grouting.Grouting is not recommended for frames installed in drywall.Assembly of frameanchor provisions.Follow manufacturers recommended procedure for assembly of frame and quantity and spacing of anchors.If not indicated, install anchors at hinge levels and directly opposite at strike jamb.Verification.Prior to installation, jobsite personnel shall ensure correct swing, size and labeling.Installation tolerances.While this document is mainly concerned with tolerances relating to the manufacturing process, openings will not function properly if the frame is not installed within recognized tolerances.Figure 1 shows examples of the accuracy to be maintained while setting frames.TOP3 Plumbing and bracing frames.Wood Spreaders see Figure 2The Contractors responsible for installation shall have available a sufficient supply of wood spreaders for bracing frames.Spreader bars for shipping purposes shall not be used as installation spreaders.Wood spreaders shall be square and fabricated from lumber no less than 1 2.Correct length is the door opening width between the jambs at the header i.Single Door 3 0 3.Length tolerance is 11.Cut clearance notches for frame stops.Spreader shall be nearly as wide as frame jamb depth for proper installation.Equipment for plumbing the frame see Figure 33.The contractor should be equipped with a carpenter level, square and wood spreaders.Where welded frames are provided with spreader bars, they shall be removed with a suitable saw or chisel and filed flush before setting frames.Bracing the frame see Figure 43.Frame bracing shall be as shown or shore to a structure above.Bracing shall be perpendicular to the intended wall.Positioning the frame.Set the frame in the desired location and level the header.Square jambs to header.Shim under jambs if necessary.With frame properly aligned, insert wood spreaders at bottom and mid height and fasten jambs to floor through floor anchors.Plumb and square jambs.Install vertical brace to support header for openings over 4 0 1.TOP4 Accessories.Install rubber silencers see Figure 54.Cut the point from a 6d box or finishing nail.Insert nail in hole to elongate rubber silencers.Moisten the end and insert rubber silencers in predrilled holes on frame stop, remove nail.The thickness of the silencer shall permit latching of door with 11.Install rubber silencers before frame erection to avoid grout filling rubber silencer holes.In some cases rubber silencers are factory installed.Extended base anchor see Figure 64.Extended base anchors are supplied upon request only.If required for tool attachment.TOP5 New masonry construction see Figure 75.Assemble frame per manufacturers instructions.Erect, brace, square and plumb frame.Fasten frame to floor through base anchors.Set second spreader at the mid height of the door opening to maintain the door opening size.Install anchors see Figure 8.Grout frame in the area of the anchors as block courses are laid up.Frames may also be supplied with anchors welded in place.Enter The Matrix Ps2 Cheats Hacking Website .Continually check plumb and square as wall progresses.TOP6 Existing masonry construction see Figure 9, Figure 1.SDI 1.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |